Tyco Compact Door Interface Unit DIU 200 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Tyco Compact Door Interface Unit DIU 200 herunter. Tyco Compact Door Interface Unit DIU 200 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
www.cemsys.com
OVERVIEW
The Compact Door Interface Unit (DIU 200) is designed primarily to provide power
to a door lock, as well as local power to a CEM reader when a high level of security
is required. It has onboard inputs which can be used to monitor conditions such as
a fire alarm or activated break-glass condition.
The DIU 200 improves door security, by allowing the installer to locate lock
controls on the secure side of a door, with an intelligent CEM reader on the
unsecured side. The DIU 200 communicates with an intelligent CEM reader over
a single pair RS485 cable. Upon a valid swipe at the card reader, the reader
will instruct the DIU (over the RS485 communications channel) to activate the
appropriate output to release the lock using a coded data signal (i.e. coded lock).
As an added benefit, the DIU 200 monitors the status of all standard door
monitoring inputs; inputs on an intelligent CEM reader are free for use as general
purpose inputs.
DIU 200 Module
• DoorInterfaceElectronics
held on one board
• Provides‘codedlock’serial
interface between door
hardware and card reader
• Onsiteselectablefor12or
24 volt lock output
• Firealarmandbreakglass
inputs for emergency door
release
• Designedforease
of installation and
maintenance using 2 part
connectors throughout
• CompliantwithEN55022
(emissions)andEN55024
(access control immunity)
• Backupbatteryconnection
for emergency power
(optional)
FEATURES
DIU 200 Module
Compact Door Interface Unit
1.DIUUnitEnclosure
2. CEM Reader
3. Sounder
4.BreakGlassUnit
5. REX/ Exit Reader or
Secure side push button
6.DoorHolder(viaoptionalBackplane)
7. Door Lock
8. Lock Sense
9.DoorPositionsensor
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - DIU 200 Module

www.cemsys.comOVERVIEWThe Compact Door Interface Unit (DIU 200) is designed primarily to provide power to a door lock, as well as local power to a CEM

Seite 2 - TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONSPHYSICALSize 115x76x10mm(4.5x3.0x0.4”)Weight 0.1KgPower-Voltage 12Vdc - Current 30mA (excluding locks and h

Kommentare zu diesen Handbüchern

Keine Kommentare